Definition of Cv Valve: The valve Cv is the flow rate (in US gal/min) of pure water at 60 o F passing through the valve when the valve disc is fully opened and the pressure differential between the tow ends of the valve is 1Lbf/in 2. Cv=V 〔 G/ ( P 1 -P 2 ) 〕 1/2 V--- Max. flow (in US gal/min) P1 --- inlet side pressure (1Lbf/in 2) P2 --- Outlet side pressure (1Lbf/in 2) G--- Specific gravity (1 for water)
|